Hybrid Energy Solutions | Huijue Group

Huijue Group energy management

Hybrid Energy Communication Base Site Solutions

Hybrid Energy Solutions for mobile communication sites, utilizing wind, solar, and diesel power for reliable, continuous energy.

Customizable Renewable Energy Solutions

Whether you need a grid-tied, off-grid, or hybrid system, with or without battery storage, and even distributed setups, we offer fully customizable renewable energy solutions tailored to your specific needs.

Data Center Energy Efficiency Solutions

Our AIoT cooling and air conditioning system saves 25% to 40% energy and reduces compressor wear by 70%. It integrates easily with existing systems, requires less than 3 hours for installation, and supports cloud-based monitoring for continuous optimization.

Previous slide
Next slide
Home > Outdoor Communication Energy air cooling Cabinet

Outdoor Communication Energy Cabinet

Introduce:

The outdoor communication energy cabinet can be suitable for various sites including communications, electricity, radio and television, transportation, entertainment, etc., ensuring stable energy supply for the backup network communication, power system, and optical distribution as well as comprehensive backup power systems.

product specification physical dimension 900mm(W)×900mm(D)×2200mm(H); IP55 protection
installation mode fall to the ground
Cooling solution Intelligent temperature control (heat exchange/air conditioning, energy-saving automatic switching refrigeration)
AC input AC input voltage Single-phase/three-phase 380VAC input (two-way input interlocking)
rectifier module 50A, fully equipped with 400A in the same slot as the photovoltaic module
Photovoltaic input Photovoltaic module capacity 550Wp*8 blocks;=4.4kw
Photovoltaic module 50A(3000W)*2
wind power wind power 600W~2000W
Fan Control Module 2KW
Energy storage backup Lithium iron phosphate battery 100AH, 51.2V; fully equipped with 4 groups, energy storage 20KWH
output characteristics DC output voltage 432VDC~58VDC (default 535VDC)
output configuration Battery: 4*125A; DC: 63A*4, 32A*4, 16A*6 AC: input 32A*3, lightning protection class C; socket: 2 channels;
Monitoring unit system signal input 1-way analog input (battery temperature); 4-way digital dry contact input
Alarm output 4 dry contacts
Communication Interface RS485
storage Up to 1000 historical alarm records
sensor Temperature and humidity, smog, access control, water immersion
environment Operating temperature -20~+75°C (-40°C can be started)
storage temperature -40℃~+75℃
Working humidity 5%~95%(no condensation)
Altitude ≤4000m (1800m~4000m, every time the altitude rises by 200m, the temperature will decrease by 1ºC.)