Hybrid Energy Solutions | Huijue Group

Huijue Group energy management
Home > Outdoor Communication Energy Cabinet HJ-SG-D02

Outdoor Communication Energy Cabinet: Empowering Connectivity in Every Environment

Detailed introduction

The series of outdoor communication energy cabinets, HJ-SG-D02 by Huijue Group, is a powerhouse designed to provide reliable energy supplies and backup systems in a wide array of outdoor communications applications. It befits extreme weather conditions and provides for continuous operation at the communication base, smart transportation hub, industrial and commercial site, and edge location.

Technical Parameters

  • Dimension: 2100900900mm, cabinet (HWD) with various installation ways available, including wall hanging and floor mounting.
  • Power Platform: A unified system allowing AC and DC input/output for adapting to various power source needs.
  • Protection Grade: IP55, C4 corrosion resistance, perfect for outdoor usage.
  • Battery Configuration: Highly efficient, safe, and long-life batteries are available in this machine for reliable energy storage.

Application Scenarios

  • Communication Base Stations: Ensures continuous power supply for critical communication infrastructure.
  • Smart Transportation: Supports the energy needs of traffic management and monitoring systems.
  • Industrial and Commercial Sites: Provides reliable backup power for businesses operating in remote or challenging locations.
  • Edge Sites: Offers stable energy solutions for data centers and network equipment in edge computing environments.

Product Features

  1. Multiple Powers Integration: Integrates photovoltaic power, wind power, and generators, supporting multiple voltage output such as AC220V, DC (-48V, -24V, -12V).
  2. Rugged Protection: IP55 and C4 corrosion-resistant, FRP construction in the cabinet housing for long life in most extreme outdoors.
  3. Energy Storage: Configurable with high-efficiency, safe, long-life batteries up to 4000 cycles.
  4. Temperature Control: Automatic regulation of the cooling fan speed through the temperature control system allows for better performance and energy efficiency.
  5. Superb Insulation: With the double-layer insulation provided, and the thermal conductivity coefficient as low as 0.024W/(m﹒K), heat is better regulated internally.
  6. Intelligent Management: Advanced EMS energy management ensures better energy savings and provides for system monitoring.
  7. Portable Design: Light enough to be manually portable, with pre-fabricated components in order to facilitate easy installation and assembling.
Outdoor communication cabinets
Communication Energy Cabinet  Layout Diagram
Outdoor Single Warehouse Cabinet internal composition
serial number name Specification unit Single unit quantity Remark In actual use
1 outdoor cabinet 2000*750*750mm (H*W*D), the cabinet frame is made of 1.5mm galvanized material, and the interior is 20mm thick with thermal insulation; front door opening operation, floor installation; separate equipment compartment and battery compartment, 4 casters;        
2 AC air conditioner AC220V, cooling capacity 1500W PCs 1 Power compartment  
3 DC air conditioner DC48V, cooling capacity 300W PCs 1 Battery compartment  
4 LED light strip Bluetooth smart LED light strip (5M+ adapter) set 1 Decorative lights  
5 USB magic cube socket conversion plug Deli for home use, 1 to 2+2USB PCs 1 For external devices  
6 Exhibition site connection cables including plugs 13A British plug connector, white PCs 1 Optional according to the socket matching on the exhibition site  
7 Wind Turbines Power 100W, S type_NE-100S_including 220V mains drive module PCs 1 It's for display, but it can't be used in practice. The power is too small, it lacks a controller, and it can't generate electricity; Wind turbines of more than 600W need to be equipped with corresponding controllers. They are larger in size and need to be fixed separately (cannot be fixed on the cabinet).
8 toolbox Contains 1 set each of Phillips screwdriver, M8 (13-15mm) and M10 double ratchet wrench (14-17mm), adjustable wrench, and Allen wrench (full set) PCs 1    
9 PDU 6 positions, 10A national standard, 19" installation, with switch, 3 meters cable PCs 1    
10 Multiple input and output power systems 4U high_AC input 32A/2P (C-level lightning protector 40KA*1_AC output 32/1P control 4-way socket interface_1 group DC 48V output 63A*4_1 group DC 24V output 32A*4_3 groups DC 12V output 32A* 4_Battery circuit breaker 63A*1_Configured 1U circuit breaker_DC24V rectifier module*1_DC12V rectifier module*1_Including power management and control unit (temperature and humidity interface*1_Smoke interface*1_Water immersion interface*1_Door sensor interface *14 channels dry contact) PCs 1 Includes: AC 220V output; DC 48V, 12V, 24V output, including remote control interface function;  
11 Lighting - inside the cabinet T5 LED/DC48V(LED type) PCs 1    
12 hot aerosol fire extinguisher QRR0.1G/SQ- Andun, thermal line 1.5 meters, feedback line 0.5 meters PCs 1 Fire protection inside the cabinet  
13 Flexible photovoltaic panels 210W, SMF210W-ETFE_Size: 1540*700*3MM_Voltage 18V PCs 1 It is for display but cannot be used in practice. The power of the photovoltaic panels is too small and the voltage is too small to generate electricity; Two photovoltaic panels of 550W or above are required. They are large in size and need to be fixed separately (they cannot be fixed on this cabinet). .
14 2 million infrared dome camera DH-IPC Dahua HD 2 million infrared 1080P dome network camera PCs 1    
15 Iron lithium battery empty shell 3U*482.6*420_48V/100AH_Requires front network port and other components, neutral PCs 3 It's for display, it's just a casing, there's no battery inside, so it can't be used in practice. If needed, real batteries are required, and the quantity can be 1 to 3 sets;
16 Swivel casters 5 inch_load bearing_with brake_rubber PCs 4    
17 Photovoltaic inverter Model, sheet metal shell 530X528X 180mm PCs 1 It's for display, it's just a casing, there's no battery inside, so it can't be used in practice. For optional use, if the load end is AC equipment, this photovoltaic inverter can be selected, and the power size is configured according to the size of the equipment;
18 Diesel generators Model, sheet metal shell, size 750X 700X 400mm, single-phase 32A oil engine plug and socket PCs 1 It's for display, it's just a casing, there's no battery inside, so it can't be used in practice. Optional, selected according to usage scenarios;
Scroll to Top